# CHNGS Electric > Gas-Insulated Switchgear 11-33 kV | OEM/ODM Factory in Yueqing, China ## Posts - [GIS Installation Checklist: 12 Checks Before Energisation](https://chngs-electric.com/gas-insulated-switchgear-installation-checklist/): Twelve pre-energisation checks for sealed switchgear: nameplate, torque, phase sequence, interlocking, gas pressure, relay settings and records. - [How to Size a Ring Main Unit: Fault Level, Cable and Load](https://chngs-electric.com/how-to-size-a-ring-main-unit/): Five sizing steps: fault level and duration, way count with spare, module width against room, cable box against cable schedule, protection. - [RMU vs VCB Switchgear: Where Each Belongs](https://chngs-electric.com/rmu-vs-vcb-switchgear/): An RMU switches a ring; a VCB panel protects a feeder. Fault level, selectivity and footprint decide which one belongs where. - [SF6 vs Solid-Insulation RMU: Which Fits Your Vault](https://chngs-electric.com/sf6-vs-solid-insulation-rmu/): Footprint, fault level, cold weather and F-gas reporting compared, plus the hybrid option most buyers forget. - [What Is a Ring Main Unit (RMU)? Functions, Types and Ratings](https://chngs-electric.com/what-is-a-ring-main-unit-rmu/): An RMU is two ring switches plus a load way in a sealed tank. The four designs, six ratings that matter, and five specification mistakes. ## Pages - [How a Gas-Insulated RMU Is Built, Step by Step](https://chngs-electric.com/insights/how-a-gas-insulated-rmu-is-built/): Catalogues show a sealed grey box and a table of rated values. - [Inside a GIS Factory: Manufacturing Notes | CHNGS](https://chngs-electric.com/insights/): Manufacturing detail, selection arguments and test practice — written by the people who build the units. - [Routine and Type Tests, IEC 62271-200 | CHNGS](https://chngs-electric.com/quality/): Ratings, interlocks, IP classification, internal arc and loss-of-service-continuity category. - [Switchgear Factory in Yueqing, China | CHNGS](https://chngs-electric.com/factory/): Sheet-metal forming, welding, gas filling, leak detection and routine testing are collocated, so non-standard module widths and OEM branding stay inside a normal lead time. - [Where Gas-Insulated RMUs Are Installed | CHNGS](https://chngs-electric.com/applications/): Loop supply, double supply and switching kiosks for 12–33 kV urban distribution. - [33 kV Gas-Insulated Switchgear, C-GIS Um 36 kV](https://chngs-electric.com/products/33-kv-gas-insulated-switchgear/): Sub-transmission level for larger plants, mines and 33 kV ring networks — 95 kV power-frequency and 170 kV lightning impulse. - [22 kV Gas-Insulated Switchgear (Um 24 kV) | CHNGS](https://chngs-electric.com/products/22-kv-gas-insulated-switchgear/): Where 11 kV runs out of capacity in suburban and rural distribution. - [13.8 kV Switchgear, ANSI 15 kV Class, 95 kV BIL](https://chngs-electric.com/products/13-8-kv-gas-insulated-switchgear/): Common in the US, Canada, Mexico, Brazil and the Gulf. - [11 kV Gas-Insulated Switchgear (Um 12 kV) | CHNGS](https://chngs-electric.com/products/11-kv-gas-insulated-switchgear/): The workhorse of urban loops and industrial parks. 42 kV power-frequency and 75 kV lightning impulse, 630 A continuous, 20 kA / 4 s short-time withstand. - [GSRM6 Gas-Insulated Ring Main Unit, 12/24 kV](https://chngs-electric.com/products/gas-insulated-ring-main-unit-gsrm6/): A sealed SF6 ring main unit that puts load-break, fuse-protection and vacuum-breaker functions in one gas tank — 325 mm per module at 12 kV, so a four-module ring position fits where an air-insulated panel would need three times the floor. - [Gas-Insulated Switchgear Range, 11-33 kV | CHNGS](https://chngs-electric.com/products/): Sealed gas-insulated platforms for 11, 13.8, 22 and 33 kV distribution duties: SF6 ring main units, solid-insulated ring main units, unit-type SF6 cubicles and fixed-type air-insulated units. - [Gas-Insulated Switchgear 11-33 kV | CHNGS](https://chngs-electric.com/): Ring main units, GIS and medium voltage switchgear from 11 kV to 33 kV — designed to the site's single-line diagram, assembled in our own plant, and routine-tested before every unit leaves the floor. - [Request a Switchgear Quotation | CHNGS](https://chngs-electric.com/contact/): The fastest route to a priced proposal is the single-line diagram plus the voltage, fault level and destination port. - [Privacy Policy](https://chngs-electric.com/privacy-policy/): This policy explains what CHNGS Electric collects when you visit chngs-electric.com or send us an enquiry, why we collect it, and how long we keep it. [comment]: # (Generated by Hostinger Tools Plugin)